1M*2.1mm*1/8,, TDX-01填充柱安裝在島津賽默飛安捷倫
產(chǎn)品名稱:1M*2.1mm*1/8,, TDX-01填充柱安裝在島津賽默飛安捷倫
產(chǎn)品型號(hào):1M*2.1mm*1/8,,
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡(jiǎn)單介紹
TDX-01填充柱安裝在島津賽默飛安捷倫:二硫化碳,室內(nèi)空氣,焦?fàn)t煤氣,芝麻香白酒,3-甲硫基丙醇,硫化氫,羰基硫,甲硫醇,二甲二硫,MTBE,裂解
1M*2.1mm*1/8,, TDX-01填充柱安裝在島津賽默飛安捷倫的詳細(xì)介紹
TDX-01填充柱安裝在島津賽默飛安捷倫
TDX-01填充柱安裝在島津賽默飛安捷倫 詳細(xì)信息:
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent Details:
TDX-01:
Black porous ball. Polyvinylidene chloride is produced by thermal decomposition at 180 ℃ and calcination at 1000 ℃ in inert gas. It has a carbon bridge structure and non-polar inert surface, high thermal stability, and long column life. Bulk density 0.6g/ml. Specific surface area 800m2/g. The aperture is 1.5-2.0nm. Grain size of 40-60 mesh, 60-80 mesh, 80-100 mesh, 100-120 mesh, 120-140 mesh.
Used as a statio nary phase for gas chromatography (with a maximum operating temperature of 500 ℃), suitable for separating low-carbon hydrocarbons, inert gases, as well as for separating oxygen and nitrogen in air and light compo nents of petroleum cracking gas, analyzing trace impurities in ethylene, and analyzing trace amounts of water, SO2, CO2, etc. in low-carbon hydrocarbons.
Name: TDX-01 Filler Column
Specification: 1M * 2.1mm * 1/8
Operating temperature: 330 ° C
Application: Separation of air, carbon monoxide, methane, and carbon dioxide
Suitable for Agilent 480589068907890782088608890
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent test spectrum:
TDX-01填充柱安裝在島津賽默飛安捷倫 詳細(xì)信息:
TDX-01:
黑色多孔小球。系聚偏氯乙烯在惰性氣體中,經(jīng)180℃熱烈解和1000℃灼燒而制成。有碳橋結(jié)構(gòu)和非極性的惰性表面,熱穩(wěn)定性高,柱壽命長(zhǎng)。堆積密度0.6g/ml.比表面積800m2/g??讖?.5~2.0nm。粒度40~60目、60~80目、80~100目、100~120目、120~140目。
用作氣相色譜的固定相(最高使用溫度500℃),適用于分離低碳烴類、惰性氣體、亦用于空氣中氧、氮的分離和石油裂解氣輕組分的分離,乙烯中微量雜質(zhì)的分析,低碳烴中微量水、SO2、CO2等的分析。
名稱:TDX-01填充柱
規(guī)格:1M*2.1mm*1/8
使用溫度:330°C
應(yīng)用:空氣,一氧化碳,甲烷,二氧化碳的分離
適用于安捷倫480,5890,6890,7890,7820,8860,8890
島津,賽默飛,瓦里安,布魯克,PE
TDX-01填充柱安裝在島津賽默飛安捷倫 測(cè)試譜圖:
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent Details:
TDX-01:
Black porous ball. Polyvinylidene chloride is produced by thermal decomposition at 180 ℃ and calcination at 1000 ℃ in inert gas. It has a carbon bridge structure and non-polar inert surface, high thermal stability, and long column life. Bulk density 0.6g/ml. Specific surface area 800m2/g. The aperture is 1.5-2.0nm. Grain size of 40-60 mesh, 60-80 mesh, 80-100 mesh, 100-120 mesh, 120-140 mesh.
Used as a statio
Name: TDX-01 Filler Column
Specification: 1M * 2.1mm * 1/8
Operating temperature: 330 ° C
Application: Separation of air, carbon monoxide, methane, and carbon dioxide
Suitable for Agilent 480589068907890782088608890
TDX-01 filling column installed on Shimadzu Thermo Fisher Agilent test spectrum:
相關(guān)產(chǎn)品
在線留言 |