HH-TBS-30,, 藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱
產(chǎn)品名稱:HH-TBS-30,, 藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱
產(chǎn)品型號(hào):HH-TBS-30,,
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡(jiǎn)單介紹
藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱:二硫化碳,室內(nèi)空氣,焦?fàn)t煤氣,芝麻香白酒,3-甲硫基丙醇,硫化氫,羰基硫,甲硫醇,二甲二硫,MTBE,裂解
HH-TBS-30,, 藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱的詳細(xì)介紹
藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱
藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱 詳細(xì)信息:
Special column for theoretical plate number determination of methanol and acetone in pharmaceutical packaging materials
Detailed information on the dedicated column for determining the theoretical tray number of methanol and acetone in pharmaceutical packaging materials:
Theoretical plate number (N, one of the column efficiency parameters in chromatography, abbreviated as column efficiency). N depends on the type and properties of the statio nary phase (particle size, particle size distribution, etc.), filling conditions, column length, type and flow rate of the mobile phase, and the properties of the substance used to measure column efficiency.
The theoretical number of plates for methanol packed columns in Pharmacopoeia 0861/0521 is generally not less than 1000.
It is very difficult for traditio nal packed columns to achieve a theoretical tray number of over 1000. To solve this problem
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed a specialized chromatographic column for determining the theoretical plate number of methanol, acetone, ethanol, etc. in Pharmacopoeia 0521. The column has been used to determine the theoretical plate number of methanol, acetone, ethanol, etc. in Pharmacopoeia 0521, with methanol reaching over 30000 and achieving good results.
Satisfactory results can be obtained on instruments such as Agilent, Shimadzu, Thermo Fisher, Varian, Bruker, PE, etc.
This column is produced through special processing for the Haohan chromatography
This column is a characteristic product of Haohan Chromatography
Name: Stainless Steel Filled Column
Specification: 3m * 1/8
model: HH-TBS-III
Application: Determination of theoretical tray number in Pharmacopoeia 0521
Applicable to: Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE
Theoretical tray number determination of methanol and acetone for pharmaceutical packaging materials using a dedicated column test spectrum:
藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱 詳細(xì)信息:
藥典0861 殘留溶劑測(cè)定法:用待測(cè)物的色譜峰計(jì)算,毛細(xì)管色譜柱的理論板數(shù)一般不低于5000;填充柱的理論板數(shù)一般不低于1000。
名稱:毛細(xì)管柱
固定相:專用
規(guī)格:30m*0.53mm
型號(hào):HH-TBS-30
應(yīng)用:藥典0861 殘留溶劑測(cè)定法,理論塔板數(shù)
適用于:安捷倫,島津,賽默飛,瓦里安,布魯克,PE
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司研制的《藥典0521甲醇丙酮的理論塔板數(shù)測(cè)定毛細(xì)管柱》,柱效高,分離好,甲醇的理論塔板數(shù)可達(dá)408638,
丙酮的理論塔板數(shù)可達(dá)143384,滿足藥典溶劑殘留;;塔板數(shù)的要求。
Special column for theoretical plate number determination of methanol and acetone in pharmaceutical packaging materials
Detailed information on the dedicated column for determining the theoretical tray number of methanol and acetone in pharmaceutical packaging materials:
Theoretical plate number (N, one of the column efficiency parameters in chromatography, abbreviated as column efficiency). N depends on the type and properties of the statio
The theoretical number of plates for methanol packed columns in Pharmacopoeia 0861/0521 is generally not less than 1000.
It is very difficult for traditio
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed a specialized chromatographic column for determining the theoretical plate number of methanol, acetone, ethanol, etc. in Pharmacopoeia 0521. The column has been used to determine the theoretical plate number of methanol, acetone, ethanol, etc. in Pharmacopoeia 0521, with methanol reaching over 30000 and achieving good results.
Satisfactory results can be obtained on instruments such as Agilent, Shimadzu, Thermo Fisher, Varian, Bruker, PE, etc.
This column is produced through special processing for the Haohan chromatography
This column is a characteristic product of Haohan Chromatography
Name: Stainless Steel Filled Column
Specification: 3m * 1/8
model: HH-TBS-III
Application: Determination of theoretical tray number in Pharmacopoeia 0521
Applicable to: Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE
Theoretical tray number determination of methanol and acetone for pharmaceutical packaging materials using a dedicated column test spectrum: