Tenax-TA吸附管采樣管聯(lián)合 氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物
產(chǎn)品名稱:Tenax-TA吸附管采樣管聯(lián)合 氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物
產(chǎn)品型號:Tenax-TA吸附管采樣管聯(lián)合
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡單介紹
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,消毒劑,氨水
Tenax-TA吸附管采樣管聯(lián)合 氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物的詳細介紹
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物 詳細信息:
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司研究考察了在常溫和冷藏條件下放置不同時間(4小時和24小時)對采樣后Tenax-Ta管中苯濃度的影響。使用Tenax-Ta管采集配氣平臺中的苯,共采集24根,采樣后分別在常溫和冷藏條件下放置4小時和24小時后使用氣相色譜進行分析,以保留時間定性,峰面積定量。結(jié)果表明,不論儲存時間長短,在冷藏條件下的Tenax-Ta管測得的苯濃度均要高于在常溫條件下放置的的Tenax-Ta管,同時前者測得的苯濃度的分布情況也要好于后者,也就是變異系數(shù)小于在常溫情況下放置的Tenax-Ta管。這是因為在常溫條件下Tenax-Ta管中吸附的污染物會有部分解析從而導(dǎo)致測得的數(shù)據(jù)較低,并且導(dǎo)致數(shù)據(jù)分布較大,因此采樣結(jié)束后應(yīng)當(dāng)將Tenax-Ta管放入裝有冰袋的保溫箱中保存并且盡快分析。
探討Tenax-TA吸附管對密閉環(huán)境中苯系物的吸附性能。方法依據(jù)《室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)》總揮發(fā)性有機物的測定方法和美國EPA TO-17標(biāo)準(zhǔn)方法,用Tenax-TA吸附管對配制的苯系物標(biāo)準(zhǔn)氣體進行采樣,以保留時間定性,峰面積定量。結(jié)果該方法對苯系物測定的相對標(biāo)準(zhǔn)偏差在4.50%~9.51%之間,苯、甲苯、對二甲苯、鄰二甲苯的低檢出濃度分別為0.04,0.65,0.50和1.60μg/m3。當(dāng)采樣體積不大于3 L時,Tenax-TA采樣管沒有穿透現(xiàn)象發(fā)生,苯系物通過Tenax-TA管吸附采樣后在室溫下可以保存40 d。結(jié)論 Tenax-TA吸附管對苯系物具有良好的吸附性能,而且設(shè)備簡單,樣品保存時間長,適合于一些特殊環(huán)境中氣體的采集。
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物 測試評價:
Determination of Benzene Series in Co nfined Enviro nment by Gas Chromatography-Mass Spectrometer
Gas Chromatography-Mass Spectrometer Determination of Benzene Series in Co nfined Environment
Tenax TA thermal analysis tube/sampling tube: 100mg, 150mg, 200mg three specifications of packing
Stainless steel tube/glass tube: 150mg, 200mg two specifications of packing
Tenax TA Thermal Desorption Tube/Sampling Tube/Used for the collection of total volatile compounds (TVOC) in indoor air, with Tenax-TA adsorbent im ported from the United States, 1/4*3.5 inches, 6mm*150mm, 6*90, special Specifications can be customized.
The Tenax TA thermal analysis tube (sampling tube) meets the requirements of the natio nal standard GB50325-2010 (2010 version) for TVOC sampling, and can also be used for various scientific research institutions to sample and analyze various plants, insects and other trace gases. It can meet the sampling requirements of HJ 583-2010 GB/T 14677-93 HJ/T 400.
Tenax-TA adsorbent chemical name: 2,6 diphenylfuran porous polymer, surface area 35m2/g; pore volume 2.4cm3/g; average pore diameter 200nm; density 0.25g/cm3.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. researched and investigated the effect of storage for different times (4 hours and 24 hours) under normal temperature and cold storage co nditions on the co ncentration of benzene in Tenax-Ta tubes after sampling. Tenax-Ta tubes were used to collect benzene in the gas distribution platform. A total of 24 pieces were collected. After sampling, they were placed under normal temperature and refrigerated co nditions for 4 hours and 24 hours and then analyzed by gas chromatography. The retention time was qualitatively and the peak area was quantified. The results show that regardless of the length of storage time, the benzene co ncentration measured by the Tenax-Ta tube under refrigerated co nditions is higher than that of the Tenax-Ta tube placed under normal temperature conditions, and the distribution of the benzene co ncentration measured by the former is also better. In the latter, the coefficient of variation is smaller than the Tenax-Ta tube placed at room temperature. This is because under normal temperature conditions, the co ntaminants adsorbed in the Tenax-Ta tube will be partially resolved, resulting in lower measured data and larger data distribution. Therefore, the Tenax-Ta tube should be placed in the tube after sampling. Store it in an incubator with an ice pack and analyze it as soon as possible.
Discuss the adsorption performance of Tenax-TA adsorption tube for benzene series in a closed environment. Methods According to the "Indoor Air Quality Standards" total volatile organic compounds determination method and the US EPA TO-17 standard method, the prepared benzene series standard gas was sampled with Tenax-TA adsorption tube, and the retention time was qualitatively and the peak area was quantified. Results The relative standard deviation of the determination of benzene series by this method was between 4.50% and 9.51%. The minimum detectable co ncentrations of benzene, toluene, p-xylene and o-xylene were 0.04, 0.65, 0.50 and 1.60μg/m3, respectively. When the sampling volume is not more than 3 L, the Tenax-TA sampling tube does not penetrate, and the benzene series can be stored for 40 d at room temperature after being absorbed and sampled by the Tenax-TA tube. Co nclusion Tenax-TA adsorption tube has good adsorption performance for benzene series, and the equipment is simple, the sample storage time is long, and it is suitable for gas collection in some special environments.
Gas Chromatography-Mass Spectrometer Determination of Benzene in Co nfined Enviro nment Test e valuation:
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物 詳細信息:
Tenax TA 熱解析管/采樣管:100mg,150mg,200mg三種規(guī)格填料
不銹鋼管/玻璃管:150mg,200mg兩種規(guī)格填料
Tenax TA 熱解析管/采樣管/用于室內(nèi)空氣中總揮發(fā)性物(TVOC)的采集,內(nèi)裝美國原裝進口Tenax-TA吸附劑, 1/4*3.5英寸 ,6mm*150mm,6*90,特殊規(guī)格可定做。
Tenax TA 熱解析管(采樣管)符合國標(biāo)GB50325-2010(2010版)對TVOC采樣的要求,也可用于各科研院校對各種植物、昆蟲等微量氣體采樣分析研究??梢詽M足HJ 583-2010 GB/T 14677-93 HJ/T 400 的采樣要求。
Tenax-TA吸附劑化學(xué)名:2,6二苯呋喃多孔聚合物,表面積35m2/g;孔體積2.4cm3/g;平均孔徑200nm;密度0.25g/cm3.
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司研究考察了在常溫和冷藏條件下放置不同時間(4小時和24小時)對采樣后Tenax-Ta管中苯濃度的影響。使用Tenax-Ta管采集配氣平臺中的苯,共采集24根,采樣后分別在常溫和冷藏條件下放置4小時和24小時后使用氣相色譜進行分析,以保留時間定性,峰面積定量。結(jié)果表明,不論儲存時間長短,在冷藏條件下的Tenax-Ta管測得的苯濃度均要高于在常溫條件下放置的的Tenax-Ta管,同時前者測得的苯濃度的分布情況也要好于后者,也就是變異系數(shù)小于在常溫情況下放置的Tenax-Ta管。這是因為在常溫條件下Tenax-Ta管中吸附的污染物會有部分解析從而導(dǎo)致測得的數(shù)據(jù)較低,并且導(dǎo)致數(shù)據(jù)分布較大,因此采樣結(jié)束后應(yīng)當(dāng)將Tenax-Ta管放入裝有冰袋的保溫箱中保存并且盡快分析。
探討Tenax-TA吸附管對密閉環(huán)境中苯系物的吸附性能。方法依據(jù)《室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)》總揮發(fā)性有機物的測定方法和美國EPA TO-17標(biāo)準(zhǔn)方法,用Tenax-TA吸附管對配制的苯系物標(biāo)準(zhǔn)氣體進行采樣,以保留時間定性,峰面積定量。結(jié)果該方法對苯系物測定的相對標(biāo)準(zhǔn)偏差在4.50%~9.51%之間,苯、甲苯、對二甲苯、鄰二甲苯的低檢出濃度分別為0.04,0.65,0.50和1.60μg/m3。當(dāng)采樣體積不大于3 L時,Tenax-TA采樣管沒有穿透現(xiàn)象發(fā)生,苯系物通過Tenax-TA管吸附采樣后在室溫下可以保存40 d。結(jié)論 Tenax-TA吸附管對苯系物具有良好的吸附性能,而且設(shè)備簡單,樣品保存時間長,適合于一些特殊環(huán)境中氣體的采集。
氣相色譜-質(zhì)譜儀測定密閉環(huán)境苯系物 測試評價:
Determination of Benzene Series in Co
Gas Chromatography-Mass Spectrometer Determination of Benzene Series in Co
Tenax TA thermal analysis tube/sampling tube: 100mg, 150mg, 200mg three specifications of packing
Stainless steel tube/glass tube: 150mg, 200mg two specifications of packing
Tenax TA Thermal Desorption Tube/Sampling Tube/Used for the collection of total volatile compounds (TVOC) in indoor air, with Tenax-TA adsorbent im
The Tenax TA thermal analysis tube (sampling tube) meets the requirements of the natio
Tenax-TA adsorbent chemical name: 2,6 diphenylfuran porous polymer, surface area 35m2/g; pore volume 2.4cm3/g; average pore diameter 200nm; density 0.25g/cm3.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. researched and investigated the effect of storage for different times (4 hours and 24 hours) under normal temperature and cold storage co
Discuss the adsorption performance of Tenax-TA adsorption tube for benzene series in a closed environment. Methods According to the "Indoor Air Quality Standards" total volatile organic compounds determination method and the US EPA TO-17 standard method, the prepared benzene series standard gas was sampled with Tenax-TA adsorption tube, and the retention time was qualitatively and the peak area was quantified. Results The relative standard deviation of the determination of benzene series by this method was between 4.50% and 9.51%. The minimum detectable co
Gas Chromatography-Mass Spectrometer Determination of Benzene in Co
相關(guān)產(chǎn)品